Precautions for the use of four-net recirculating screen changer
1, under any circumstances, do not allow in the oil pump motorized rotation, installation and removal of the screen changer screen block and adjust the structural components.
2, in the normal screen change, adjust the guide slide frame and the position of the screen block, do not allow the phenomenon of "over position".
3、Equipment placed more than 10 days without use and re-open the machine, should first check the screen changer action is sensitive and reliable.
4、Strictly prohibited in the high temperature without lubrication, repeatedly pushing and pulling the screen block, in order to prevent strains on the mating surface.
5, circulating hydraulic non-stop screen changer normal production, the filter block on both sides should be a trace of melt overflow. In order to profit slippery, such as no overflow or newly installed filter block, change the screen on both sides of the filter block should be lubricated with silicone oil.
four-net recirculating hydraulic net changer
Four-net recirculating screen changer care and maintenance
1, cyclic hydraulic non-stop screen changer generally do not need special maintenance, in the use of the main body should be kept clean, pay attention to the observation of the working status of the instruments and the surface of the slider with or without scars.
2, in each screen change, due to the high temperature of the filter block, you should put on heat-insulating gloves, to stop it from falling, fall.
3、If there is any failure, it should stop the machine in time and ask the experienced maintenance personnel to check and repair, and it is forbidden to work with failure.
Email: info@battemachinery.com
WhatsApp: +86 158 38331071
Previous:Hot melt adhesive double column hydraulic screen changer